Tampon Holder Hu-Friedy Handle Number 2
The Porte-tampon Hu-Friedy manche #2 - Hu-Friedy is a medical device manufactured by Hu-Friedy Mfg. Co., LLC.
- Compliance: Medical device Class I.
- Manufacturer: Hu-Friedy Mfg. Co., LLC.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Hu-Friedy cotton pellet holder handle #2?
The Hu-Friedy cotton pellet holder handle #2 is a specific manual instrument designed by Hu-Friedy Mfg. Co., LLC for interventions in the oral environment. This device, often referred to as dental cotton pliers, consists of an ergonomic #2 type handle and a working end adapted for the secure gripping of pellets, gauze, or cotton. Its robust design allows practitioners to manipulate absorbent materials with great stability, thus facilitating the maintenance of a clear operative field. As an instrument from the Hu-Friedy brand, it benefits from the expertise of a recognized manufacturer in the field of surgical instrumentation, guaranteeing a response adapted to the requirements of clinicians in oral surgery.
What are the clinical indications for the cotton pellet holder?
This dental surgery cotton pellet holder is primarily indicated for fluid management and asepsis of the operative site. In implant or periodontal surgery, it is used to transport and hold cotton pellets or sterile compresses to perform compression hemostasis or to clean a specific area before an incision. It also serves for the application of antiseptic solutions or topical medications on soft tissues or inside extraction sockets. The surgical cotton pliers allow reaching restricted access areas without obstructing the surgeon's visibility, thus ensuring optimal site preparation before the placement of implants or bone grafts.
What are the technical characteristics of this instrument?
The Hu-Friedy cotton pellet holder is distinguished by its #2 handle, offering balance and a grip adapted to repetitive movements in the dental office. Although the exact composition is not specified in the source data, this instrument from the INSTRU category is designed to withstand standard decontamination and sterilization cycles in a medical environment. The configuration of the surgical cotton pliers is optimized to exert constant clamping pressure, preventing the slipping of soft materials during handling. This device does not include a needle and focuses exclusively on the function of gripping and transferring sterile consumables during pre-operative and per-operative phases.
What are the contraindications for the use of this device?
According to the information provided by the manufacturer Hu-Friedy Mfg. Co., LLC, there are no specific listed medical contraindications, other than the fact that the use of this instrument is strictly reserved for qualified healthcare professionals. As with any surgical cotton forceps type instrument, its use should be avoided if the integrity of the instrument is compromised or if the practitioner does not master the associated surgical technique. It is imperative to read the instructions carefully before use to ensure compliance with safety protocols. The instrument must be used in accordance with its intended use to avoid any risk of iatrogenic injury during the manipulation of tissues or pellets.
What are the maintenance and handling precautions?
The Hu-Friedy cotton pellet holder handle #2 is a non-absorbable and reusable instrument that requires a strict sterilization protocol between each patient. Being classified as Class I, it must be processed according to the standard cleaning, disinfection, and steam sterilization (autoclave) guidelines recommended by Hu-Friedy. Practitioners must inspect the instrument before each use to detect any signs of wear or corrosion. Particular attention should be paid to the hinge and the jaws of the dental cotton pliers to ensure optimal functionality. Compliance with maintenance cycles extends the life of the instrument and ensures microbiological safety during surgical interventions.
Who is the manufacturer and what standards are respected?
The device is manufactured by Hu-Friedy Mfg. Co., LLC, located at 3232 N. Rockwell St. Chicago, Il 60618 USA. This cotton pellet holder is a Class I medical device, which means it meets the basic regulatory requirements for non-invasive or reusable surgical instruments. Although specific CE marking is not mentioned in the source documentation, compliance with Hu-Friedy manufacturing standards ensures consistent quality. The product is exclusively reserved for healthcare professionals, highlighting the importance of adequate training for its handling. The manufacturer's indications and warnings must be scrupulously followed to ensure use in accordance with current safety standards.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.
Specifications
| Manufacturer | Hu-Friedy |