Twist drill, Ø 1.0 mm, L=50 mm, stop 14 mm Drill - Titamed
The Twist drill, Ø 1.0 mm, L=50 mm, stop 14 mm Drill - Titamed is a medical device manufactured by Titamed BV.
- Manufacturer: Titamed BV.
- Reference: IT105014.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Titamed Ø 1.0 mm Twist drill?
The Titamed Twist drill is a precision rotary instrument intended for bone and implant surgery. This device has a diameter of 1.0 mm and a total length of 50 mm. Its structure is characterized by a 1mm helical bit designed for efficient evacuation of bone debris during drilling. Manufactured by Titamed BV, this tool is specifically developed to offer trajectory stability when creating the implant site or initial osteotomy. Its robust design meets the requirements of daily surgical practice in dental offices or hospital environments.
What are the clinical indications for this 1.0 mm drill?
This 1 0 implantology drill is primarily indicated for performing pilot holes or precision marking on alveolar ridges. In bone surgery, it allows for defining the future insertion axis of an implant or preparing the passage for fixation screws. Its 1.0 mm fineness makes it a tool of choice for narrow anatomical areas or clinical cases requiring a minimally invasive approach. It is used by dental surgeons and implantologists to ensure clean bone preparation, limiting thermal heating thanks to its cutting geometry optimized for dense or cancellous bone tissue.
What are the technical characteristics of the IT105014 model?
The IT105014 model from Titamed is distinguished by strict technical dimensions for increased operative safety. It has a cutting diameter of 1.0 mm and a shaft length of 50 mm. The major feature of this reference is its fixed stop located at 14 mm, which acts as a physical depth gauge. This safety feature prevents any accidental over-drilling beyond the defined measurement, thus protecting underlying anatomical structures such as the alveolar nerve or maxillary sinus. This 1 0 helical bit is compatible with standard surgical contra-angles accepting rotary instruments of this length.
What are the contraindications for the use of this instrument?
Contraindications for the use of this bone surgery drill include clinical situations where bone density is insufficient to guarantee instrument stability or when interdental space does not allow for secure access. Use is prohibited in cases of uncontrolled systemic pathology affecting bone healing. It is imperative not to use the instrument if it shows signs of wear, deformation, or loss of sharpness, as this would increase the risk of thermal bone necrosis. The practitioner must ensure the absence of known hypersensitivity to the metallic components of the instrument before any intervention.
What are the maintenance precautions for this Titamed equipment?
As a non-resorbable cutting instrument used in a sterile environment, the Titamed Twist drill requires a strict decontamination and sterilization protocol between each use, in accordance with the instructions from the manufacturer Titamed BV. Precautions include thorough cleaning of the 1mm helical bit flutes to remove any organic residue. It is recommended to check the integrity of the 14 mm stop before each procedure. A visual inspection under magnification allows for the detection of potential micro-cracks. Storage in a dry and protected environment is essential to maintain the mechanical properties of the surgical steel.
Who is the manufacturer and what standards are respected?
The product is manufactured by Titamed BV, a recognized manufacturer in the field of medical devices for osteosynthesis and implantology. Although the specific regulatory class and CE marking are not detailed in the technical data provided for this IT105014 reference, Titamed products are generally designed according to rigorous industrial quality standards. For any precise information regarding ISO certifications, the risk class (generally Class IIa for invasive surgical rotary instruments), or the CE certificate of conformity, it is imperative to refer to the instructions for use and the original labeling delivered with the device.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Titamed |
| Tags | |
|---|---|
| Tags | |