Dental Surgical Instrument - Helmut Zepf Tooth Extraction Forceps (12.067.01Z)

https://www.delynov.fr/web/image/product.template/23403/image_1920?unique=27f4768

The DAVIER FORME ANGLAISE FIGURE 67 A - Pince à extraction dentaire Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 12.067.01Z.
  • Reserved for healthcare professionals. Read instructions carefully before use.

111.23 € 111.23 EUR 111.23 € Tax Included

111.23 € Tax Included

(111.23 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf extraction forceps figure 67 A?

The English pattern forceps figure 67 A, bearing reference 12.067.01Z, is a high-quality manual instrument manufactured by Helmut Zepf Medizintechnik GmbH. Specifically designed for dental extraction, this instrument is made of medical stainless steel, a material chosen for its resistance and compatibility with hospital decontamination processes. Its structure is adapted for gripping hard tissues on the upper arch, offering the practitioner a stable grip during avulsion procedures. As a Class I device, it meets the regulatory requirements for non-invasive or short-term invasive dental instrumentation.

What are the clinical indications?

This device is indicated for oral surgery procedures requiring the extraction of teeth or roots. More specifically, figure 67 A is commonly used for wisdom tooth extraction in the maxillary sector. The instrument allows for grasping the crown or residual root in order to apply the rotation and traction forces necessary to rupture the periodontal ligament. Its use is strictly reserved for qualified healthcare professionals operating in dental practices or hospital environments for dental and implant surgery procedures.

What are the technical characteristics?

The 12.067.01Z forceps is distinguished by its medical stainless steel design, guaranteeing durability through repeated reprocessing cycles. It is an English pattern instrument, a classic configuration appreciated for its optimal force transmission. The manufacturer, Helmut Zepf, delivers this product in a non-sterile state, requiring a strict protocol of cleaning, disinfection, and sterilization before the first use and between each patient. The instrument's design does not define a maximum limit of processing cycles, as this depends on visible wear and the care taken during maintenance.

What are the contraindications for use?

The main contraindication related to the use of this forceps is known patient hypersensitivity or intolerance to metals, particularly to the components of medical stainless steel. If a hypersensitivity reaction is triggered upon contact with the instrument, the procedure must be immediately stopped and necessary medical measures must be taken. Furthermore, the use of the instrument is contraindicated if it shows visible damage such as cracks, breaks, or defects on the active parts, as this could compromise patient safety and the effectiveness of the procedure.

What are the precautions for use and maintenance?

All Helmut Zepf instruments must imperatively be cleaned, disinfected, and sterilized before their first use and after each subsequent use. It is crucial to inspect the instrument before each surgical step to detect any trace of wear or corrosion. The use of damaged products is strictly prohibited. The reprocessing process must follow validated protocols for stainless steel. Although no cycle limit is set by the manufacturer, the device's longevity directly depends on compliance with cleaning instructions and systematic verification of the integrity of the cutting edges and hinges.

Who is the manufacturer and what standards are respected?

This forceps is manufactured by Helmut Zepf Medizintechnik GmbH, a company located in Seitingen-Oberflacht, Germany. The product is classified as a Class I medical device according to current regulations. The manufacturer guarantees the compliance of its instruments with the safety and performance requirements for manual dental instruments. Each device is identified by a precise technical reference (12.067.01Z) ensuring its traceability. Professionals can refer to the manufacturer's instructions to ensure compatibility with other products used during surgical interventions.


State of the art

Guided bone regeneration (GBR) in implantology relies on membrane fixation quality.