DENTAL EXTRACTION FORCEPS. ENGLISH PATTERN. FIGURE 79. - Helmut Zepf (12.079.00Z) - Delynov
The DAVIER. FORME ANGLAISE. FIGURE 79. - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.079.00Z.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf figure 79 extraction forceps?
The Helmut Zepf extraction forceps (reference 12.079.00Z) is a manual dental instrument of English pattern. Manufactured in medical stainless steel by Helmut Zepf Medizintechnik GmbH, this device is specifically designed for tooth extraction procedures. As an instrument in the CONSO category, it features a robust structure adapted to the mechanical stresses of oral surgery. This model, identified as figure 79, complies with German manufacturing standards to ensure reliable handling during clinical interventions.
What are the clinical indications?
This English pattern dental forceps is indicated for the extraction of roots and teeth, primarily in the lower jaw (mandible). Its use is strictly reserved for qualified healthcare professionals within the framework of dental, implant, or periodontal surgeries. The instrument allows for a firm grip on the tooth to perform the rotation or tilting movements necessary for avulsion. It is imperative to check the condition of the instrument, particularly the absence of cracks or damage to the working parts, before each intervention.
What are the technical characteristics?
The Helmut Zepf 12.079.00Z extraction forceps is characterized by its high-quality medical stainless steel design. It is a non-sterile instrument upon delivery, requiring a complete reprocessing cycle before the first use and after each subsequent use. Its English pattern figure 79 is optimized for access to mandibular areas. Due to its metallic composition and robustness, the manufacturer does not define a maximum limit for sterilization cycles; reprocessing depends on visible wear and the structural integrity of the device during pre-surgical checks.
What are the contraindications for use?
The main medical contraindication mentioned by the manufacturer Helmut Zepf Medizintechnik GmbH concerns known hypersensitivity or intolerance of the patient to metals, particularly to components of medical stainless steel. If a hypersensitivity reaction is triggered upon contact with the instrument, the procedure must be immediately stopped and necessary medical measures must be taken. Additionally, the use of the instrument is contraindicated if it shows visible damage such as cracks, breaks, or defects on the cutting edges.
What are the maintenance and reprocessing precautions?
All Helmut Zepf instruments must be cleaned, disinfected, and sterilized before their first use and after each patient. The reprocessing process is crucial for clinical safety. It is imperative to clean each product before proceeding to sterilization. The practitioner must inspect the instrument for any visible wear or corrosion. The use of damaged products is strictly prohibited. Although no cycle limit is set, the longevity of the device depends on strict compliance with cleaning protocols and the absence of mechanical degradation on the steel.
Who is the manufacturer and what standards are met?
This device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This extraction forceps is classified as a Class I medical device according to current regulations. It meets the safety and performance requirements for manual dental instruments. As a Class I product, it is intended exclusively for professional use by trained practitioners. Traceability is ensured by the technical reference 12.079.00Z, guaranteeing the origin and compliance of the equipment supplied by Delynov.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |