Skip to Content

English pattern dental extraction forceps figure 18 - Helmut Zepf (12.218.00Z) - Delynov

https://www.delynov.fr/web/image/product.template/24629/image_1920?unique=334f6d5

The Davier forme anglaise figure 18 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 12.218.00Z.
  • Reserved for healthcare professionals. Read instructions carefully before use.

133.28 € 133.28 EUR 133.28 € Tax Included

133.28 € Tax Included

(133.28 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf figure 18 forceps?

The Helmut Zepf figure 18 forceps (reference 12.218.00Z) is a manual dental instrument of English pattern. Manufactured by Helmut Zepf Medizintechnik GmbH, this device is designed in high-quality medical stainless steel. It belongs to the category of consumables for oral surgery and is specifically structured to meet the needs of practitioners during avulsion procedures. As a manual instrument, it allows direct transmission of force during manipulation. This product is delivered non-sterile and requires a complete preparation protocol before any clinical use in the office or operating room.

What are the clinical indications?

The intended purpose for this forceps is its use as a manual dental instrument during surgical procedures. It is primarily indicated for dental extraction procedures where the English pattern figure 18 is required. This instrument allows the dental surgeon or oral surgeon to firmly grasp the tooth to perform the necessary luxation and avulsion movements. Its use is strictly reserved for qualified healthcare professionals. The official indication from the manufacturer Helmut Zepf limits its application to the function of manual instrumentation within the framework of standard dental care and oral surgery.

What are the technical characteristics?

The Helmut Zepf forceps code 12.218.00Z is characterized by its manufacture in medical stainless steel, a material chosen for its resistance to cleaning and sterilization cycles. It is a Class I device according to current regulations. On a technical level, the product design and the materials used do not allow for the definition of a maximum limit of processing cycles, although the instrument must be inspected before each use. The practitioner must imperatively check for the absence of visible damage, such as cracks, breaks, or defects on the cutting edges, in order to guarantee surgical safety.

What are the contraindications for use?

The main medical contraindication mentioned by the manufacturer Helmut Zepf Medizintechnik GmbH concerns hypersensitivity to metals. An intolerance reaction may occur in the patient upon contact with the medical stainless steel of the instrument. If such a hypersensitivity reaction is triggered during the intervention, the procedure must be immediately stopped and the necessary medical measures must be taken. It is therefore crucial to question the patient about their allergic history before any use. Furthermore, the use of the instrument is contraindicated if it shows visible signs of wear or structural damage.

What are the maintenance and safety precautions?

All Helmut Zepf instruments must be cleaned, disinfected, and sterilized before the first use and after each subsequent use. It is imperative to perform a complete cleaning to remove all residue before the sterilization cycle. The products are delivered non-sterile by the manufacturer. Before each intervention, the practitioner must check compatibility with other products used. The use of damaged or worn instruments is strictly prohibited to avoid any risk of breakage or injury. Due to its composition, reprocessing must follow rigorous protocols to maintain the integrity of the stainless steel.

Who is the manufacturer and what standards are respected?

The official manufacturer of this device is the company Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This forceps is a Class I medical device, complying with regulatory requirements for manual dental instruments. The manufacturer specifies that the product must be handled exclusively by healthcare professionals. Although the maximum number of processing cycles is not fixed, the durability of the instrument depends on compliance with the cleaning and sterilization instructions recommended by Helmut Zepf. Following the manufacturer's instructions guarantees the maintenance of the performance of the medical stainless steel instrument.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument