English Pattern Extracting Forceps Fig. 321 - Helmut Zepf (12.221.90ZD)
The Davier forme anglaise figure 321 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 12.221.90ZD.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf English pattern extraction forcep figure 321?
The English pattern extraction forcep figure 321, referenced under code 12.221.90ZD by Delynov, is a manual dental instrument manufactured by Helmut Zepf Medizintechnik GmbH. This device is designed in high-quality medical stainless steel, a standard material for surgical instrumentation due to its resistance and ability to undergo repeated decontamination cycles. As a Class I instrument, it is specifically intended for use by qualified healthcare professionals during in-office surgical procedures. Its structure meets the requirements of the classic English pattern to facilitate extraction maneuvers.
What are the clinical indications for this extraction forcep?
The primary indication for this Helmut Zepf instrument is its use as a manual dental instrument during oral surgery procedures. It is employed by the practitioner to grasp, mobilize, or extract dental elements or fragments during avulsion acts. Its use is strictly reserved for trained healthcare professionals. The manufacturer specifies that the intended purpose is manual assistance during dental care, requiring precise handling to ensure the effectiveness of the operative act while respecting current clinical protocols.
What are the technical characteristics of the 12.221.90ZD forcep?
This Helmut Zepf forcep is characterized by its medical stainless steel construction, guaranteeing compatibility with hospital sterilization processes. It belongs to Class I of medical devices. Although the manufacturer does not define a maximum limit for processing cycles due to the nature of the materials used and the design of the instrument, the service life depends on maintenance and the absence of visible damage. The instrument is delivered non-sterile and must imperatively undergo a complete cleaning, disinfection, and sterilization protocol before its first use and after each intervention.
What are the contraindications for the use of this instrument?
The main contraindication mentioned by Helmut Zepf Medizintechnik GmbH concerns metal intolerance. Contact with this medical stainless steel instrument may cause a hypersensitivity reaction in certain sensitive patients. If such an allergic or intolerance reaction occurs during the intervention, the procedure must be immediately interrupted and necessary medical measures must be taken. It is therefore recommended to check the patient's allergic history before any use of metallic instrumentation.
What are the maintenance and safety precautions?
Patient and practitioner safety relies on rigorous maintenance. Before each use, it is crucial to visually inspect the Helmut Zepf instrument for any visible damage or wear, such as cracks, breaks, or defects on the cutting edges. The use of damaged or worn products is strictly prohibited. Before the first use and for all subsequent uses, the forcep must be cleaned, disinfected, and sterilized. The manufacturer emphasizes that it is very important to clean each product before it goes into the autoclave to guarantee effective sterilization and prevent cross-contamination.
Who is the manufacturer and what standards are respected?
The extraction forcep is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This device is classified as Class I according to the current regulations on medical devices. The manufacturer ensures the traceability and quality of its instruments through rigorous manufacturing protocols. In accordance with European directives, the instrument must be handled exclusively by healthcare professionals. Reprocessing of the instrument is possible thanks to its robust design, although the exact number of achievable cycles must be determined by the user based on the state of wear observed during regular inspections.
State of the art
Surgical medical consumables play a decisive role in operative safety.