Skip to Content

Surgical dental extraction forceps, American pattern type Fig. 69 - Helmut Zepf (14.069.00) - Delynov

https://www.delynov.fr/web/image/product.template/170811/image_1920?unique=1dc82d0

The Davier chirurgical pour extraction dentaire, forme américaine type Fig. 69 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 14.069.00.
  • Reserved for healthcare professionals. Read instructions carefully before use.

106.58 € 106.58 EUR 106.58 € Tax Included

106.58 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf 14.069.00 surgical forceps?

The Helmut Zepf surgical forceps, referenced under code 14.069.00, is a specialized manual instrument intended for dental extraction. This model adopts the American pattern type Fig. 69, a configuration recognized in odontological instrumentation for its specific morphology. Manufactured by Helmut Zepf Medizintechnik GmbH, this device is designed to meet the requirements of oral surgery. Although precise details on the composition are not specified in the source data, this type of Helmut Zepf instrument is traditionally used for the manipulation of hard structures in a clinical setting. Its structure is optimized to offer a stable grip, essential during avulsion maneuvers.

What are the clinical indications for this extraction forceps?

This extraction forceps is primarily indicated for oral surgery procedures requiring the removal of teeth or root structures. The American pattern Fig. 69 is particularly sought after for the extraction of fragments or roots remaining in place after a crown fracture or during advanced tooth decay. Dental surgeons and implantologists use this Helmut Zepf instrument to ensure a firm grip on mineralized tissues. Its use is part of alveolar sanitation protocols before implant placement or as part of emergency treatments aimed at eliminating infectious foci of dental origin.

What are the technical characteristics of the Fig. 69 forceps?

The Helmut Zepf Fig. 69 forceps is distinguished by its technical design compliant with American pattern standards. Carrying the reference 14.069.00, it features a beak geometry adapted for root grasping. Unlike sutures, this instrument does not include a needle, but is defined by the articulation of its handles and the precision of its working parts. The design by Helmut Zepf Medizintechnik GmbH ensures efficient transmission of the force exerted by the practitioner to the intervention area. This tool is a key element for managing fragment extraction cases, allowing for a targeted approach and rigorous manipulation of dental debris.

What are the contraindications for the use of this instrument?

Contraindications for the use of this Helmut Zepf forceps generally fall under the clinical judgment of the practitioner and the general health status of the patient. It should not be used in situations where a simple extraction is not recommended, such as in the presence of certain uncontrolled systemic pathologies or severe coagulation disorders without medical supervision. On a technical level, the use of the instrument is contraindicated if the root morphology does not match the curvature of the Fig. 69 type beaks, which could lead to a risk of unwanted bone or dental fracture. Current surgical protocols should be systematically consulted.

What are the maintenance and durability precautions?

As it is a non-resorbable metallic surgical instrument, the Helmut Zepf forceps requires a strict decontamination and sterilization protocol after each use. Although cleaning specificities are not detailed here, the durability of Helmut Zepf instrumentation depends on compliance with the sterilization cycles recommended by the manufacturer Helmut Zepf Medizintechnik GmbH. Practitioners must regularly inspect the condition of the hinge and the integrity of the beaks to ensure safety of care. Careful handling during manual or automatic cleaning phases prevents premature wear and maintains the device's grasping capabilities during fragment extractions.

Who is the manufacturer and what standards are respected?

The official manufacturer of this medical device is Helmut Zepf Medizintechnik GmbH, a recognized player in the field of dental and surgical instrumentation. Manufacturing follows the quality standards specific to this German company to guarantee the reliability of the product referenced 14.069.00. Regarding specific certifications such as regulatory class or CE marking, this information is not specified in the provided technical documentation. It is imperative for the user to consult the product labeling and the instructions for use provided by Helmut Zepf to verify compliance with local and European regulations in force at the time of purchase.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument