Nevius surgical dental extraction forceps, American pattern, Figure 88-L - Helmut Zepf (14.088.15) - Delynov
The Davier chirurgical Nevius, forme américaine, figure 88-L - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 14.088.15.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf Nevius surgical forceps?
La pince chirurgicale Nevius est un instrument d'extraction de haute précision. Ce modèle spécifique, référence 14.088.15, adopte le motif américain figure 88-L. Elle est conçue pour répondre aux exigences des praticiens lors des procédures d'exodontie complexes. Sa structure est pensée pour s'adapter parfaitement à la morphologie des molaires gauches de l'arcade supérieure. En tant qu'instrument de la catégorie CONSO chez Delynov, elle représente un standard de qualité pour l'instrumentation manuelle en chirurgie orale.
What are the clinical indications for this extraction forceps?
Cette pince Nevius est exclusivement indiquée pour l'extraction des molaires supérieures gauches. En chirurgie orale et implantologie, elle permet au praticien de réaliser l'avulsion de dents dont la couronne est encore partiellement ou totalement présente. La configuration 88-L est spécifiquement conçue pour contourner les obstacles anatomiques de la zone maxillaire gauche et saisir efficacement les racines des molaires gauches. Son utilisation est courante lors des phases de préparation de site avant la pose d'implants ou pour l'élimination de foyers infectieux. Dispositif médical de Classe I. Marquage CE. Lire attentivement les instructions figurant dans la notice d'utilisation ou sur l'étiquetage.
What are the technical characteristics of model 14.088.15?
The Helmut Zepf reference 14.088.15 forceps is distinguished by its American Nevius pattern, characterized by an asymmetry of the beaks. This figure 88-L has a pointed tip intended to fit into the furcation of the buccal roots of the upper left molar, while the other beak ensures stability on the palatal side. This design allows for optimal transmission of forces during the extraction of left molars. The instrument is designed to offer a stable and secure grip, essential for controlling the surgical gesture during the rupture of the ligament fibers.
What are the contraindications for the use of this instrument?
The contraindications for the use of the Nevius figure 88-L forceps are mainly related to the anatomy of the surgical site. It must not be used for the extraction of right molars or mandibular teeth, as its curvature and the orientation of its beaks are strictly dedicated to the upper left molar. Furthermore, its use may be contraindicated in cases of extreme bone fragility or immediate proximity to sensitive anatomical structures if the gesture is not perfectly mastered. As with any surgical instrument, a known allergy to the metallic components of the alloy constitutes a contraindication.
What are the maintenance precautions for this non-resorbable device?
As a reusable and non-resorbable surgical instrument, the Helmut Zepf forceps requires a rigorous decontamination and sterilization protocol after each intervention. Practitioners must follow the recommendations of the manufacturer Helmut Zepf Medizintechnik GmbH regarding manual or ultrasonic cleaning, as well as autoclave cycles. It is imperative to check for the absence of organic debris in the hinges and on the beaks before sterilization. Proper maintenance ensures the maintenance of the mechanical properties of the steel and prevents any risk of cross-contamination between patients.
Who is the manufacturer and what standards are respected?
Ce dispositif est officiellement fabriqué par Helmut Zepf Medizintechnik GmbH, un acteur reconnu dans l'instrumentation de haute technologie pour la chirurgie orale. Bien que les détails spécifiques du marquage CE ou de la classe réglementaire ne soient pas mentionnés dans cette fiche technique, les produits Helmut Zepf sont conçus selon les normes de qualité rigoureuses de l'industrie médicale allemande. Pour toute information précise concernant les certifications réglementaires ou la conformité aux normes ISO en vigueur, les praticiens doivent se référer à la notice d'utilisation ou à la documentation technique fournie avec l'instrument.
State of the art
Surgical medical consumables play a decisive role in operative safety.