American pattern surgical dental extraction forceps with serrated handles, figure 89 - Helmut Zepf (14.089.00) - Delynov
The Davier chirurgical de forme américaine à manches striés, figure 89 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 14.089.00.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf figure 89 surgical forceps?
The Helmut Zepf surgical forceps, figure 89, is a manual instrument specifically developed for dental extraction in oral surgery. This model, identified under reference 14.089.00, is distinguished by its American pattern structure. Its design is based on a robust architecture adapted to the mechanical stresses of avulsion procedures. The instrument is equipped with serrated handles, a technical feature aimed at optimizing the practitioner's grip during interventions. Manufactured by Helmut Zepf Medizintechnik GmbH, this device is part of the specialized instrumentation range for dental surgeons and implantologists seeking tools that comply with current clinical practice standards.
What are the clinical indications for this instrument?
The Helmut Zepf figure 89 forceps is indicated for exodontia procedures. In oral and implant surgery, it is used for the firm grasping of the dental structure in order to perform the rotation or tilting movements necessary to rupture the periodontal ligament. Its specific American pattern directs its use towards precise clinical sectors, facilitating access and the application of forces during extraction. This instrument is particularly requested during site preparation phases for immediate or delayed implant placement, requiring controlled manipulation to preserve the integrity of the surrounding alveolar bone plates.
What are the technical characteristics of the 14.089.00 forceps?
The main technical characteristics of this Helmut Zepf forceps are based on its figure 89 geometry and its American pattern configuration. The major distinctive element of this model lies in its serrated handles. This surface texture is designed to provide a stable contact interface between the surgeon's glove and the instrument, thereby reducing the risk of slipping during the application of significant pressure. Reference 14.089.00 guarantees precise traceability of the model within the Helmut Zepf Medizintechnik GmbH manufacturer's catalog. Although exact dimensions are not specified, figure 89 corresponds to a curvature and beak shape adapted to specific tooth groups.
What are the contraindications for the use of this forceps?
Contraindications for the use of the Helmut Zepf figure 89 forceps are mainly related to the patient's clinical status and the suitability of the instrument for the target tooth. It must not be used if the morphology of the tooth or root does not correspond to figure 89, at the risk of causing a root fracture or damaging adjacent soft tissues. In general, the use of surgical steel instruments is contraindicated in patients with a known hypersensitivity to metals, particularly nickel or chromium, if these components are included in the alloy. The practitioner must evaluate the residual strength of the dental crown before any application of force to avoid intraoperative complications.
What are the maintenance precautions for this non-absorbable device?
As a reusable surgical instrument, the Helmut Zepf forceps requires a strict decontamination, cleaning, and sterilization protocol between each patient. Being a non-absorbable device intended for external use on hard and soft tissues, its durability depends on compliance with the autoclave sterilization cycles recommended by the manufacturer. It is essential to check for the absence of biological debris in the serrations of the handles and at the joint level before sterilization. Complete drying is imperative to prevent any corrosion phenomena. The practitioner must regularly inspect the condition of the beaks and the fluidity of the hinge to guarantee the safety and effectiveness of the surgical act.
Who is the manufacturer and what standards are respected?
This medical device is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer in the field of dental and surgical instrumentation. Although specific data regarding the regulatory class or CE marking are not detailed in the source documentation, Helmut Zepf products are designed according to the rigorous quality standards specific to the German medical industry. Professionals are invited to systematically refer to the instructions for use and product labeling to verify current certifications, such as the CE marking, and ensure the device's compliance with the requirements of the European Medical Device Regulation (MDR).
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.