Skip to Content

CRYER, DENTAL EXTRACTION FORCEPS FOR CHILDREN, FIG. 150-S, AMERICAN PATTERN, - Helmut Zepf (14.150.05) - Delynov

https://www.delynov.fr/web/image/product.template/170819/image_1920?unique=d457bf7

The CRYER, DAVIER POUR ENFANTS,FIG. 150-S, FORME AMÉRICAINE,- Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 14.150.05.
  • Reserved for healthcare professionals. Read instructions carefully before use.

106.58 € 106.58 EUR 106.58 € Tax Included

106.58 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf Cryer forceps Fig. 150-S?

The Cryer forceps, referenced under code 14.150.05 by Helmut Zepf, is a manual surgical instrument specifically designed for the practice of pediatric dentistry. This model, American pattern and designated by figure 150-S, is distinguished by reduced dimensions compared to adult models, allowing for more precise manipulation in the narrow oral cavity of a child. Manufactured by Helmut Zepf Medizintechnik GmbH, this instrument is intended for simple or complex dental extractions. Its monoblock structure ensures optimal force transmission during luxation and avulsion movements, while respecting the specific anatomy of the surrounding tissues in the young patient.

What are the clinical indications for this pediatric forceps?

This milk teeth extraction forceps is primarily indicated for dental avulsion procedures in pediatric patients. It is used during oral surgeries requiring the extraction of temporary teeth or residual roots. The Fig. 150-S configuration is adapted to specific alveolar sectors where access is limited by the growth of the jaws. Practitioners use this instrument to secure the grip on the crown or the neck of the tooth, thus facilitating the rotation or rocking movements necessary to break the periodontal ligament. Its use is part of conservative care or orthodontic treatments requiring serial extractions.

What are the technical characteristics of model 14.150.05?

Model 14.150.05 is characterized by its American pattern, an architecture recognized for its particular ergonomics in the beaks and handles. Unlike European patterns, this Cryer forceps features a curvature and working angle optimized for difficult access. The terminology Fig. 150-S precisely designates its 'Small' size, adapted to the practitioner's hand and the child's morphology. The design by Helmut Zepf guarantees a precise fit of the beaks, allowing a firm grip without risk of excessive slipping on smooth dental surfaces. The instrument is designed to withstand standard thermal cleaning and sterilization cycles in the dental office.

What are the contraindications for the use of this forceps?

Although the source data does not list specific contraindications, the use of this forceps is contraindicated in clinical situations where the anatomy of the tooth to be extracted does not correspond to the opening or shape of the Fig. 150-S beaks. It must not be used on permanent adult dentition, as its reduced size could lead to instrument fracture or insufficient grip, increasing the risk of alveolar trauma. As with any surgical instrument, its use is prohibited if the device shows signs of wear, corrosion, or deformation. It is the practitioner's responsibility to evaluate the appropriateness of the instrument based on the prior radiological examination.

What are the maintenance precautions for this non-resorbable instrument?

As a reusable metallic instrument, this forceps requires a rigorous decontamination and sterilization protocol after each intervention. Precautions include manual or ultrasonic cleaning to remove organic debris, followed by thorough rinsing. Sterilization must be carried out in an autoclave according to the parameters recommended by the manufacturer Helmut Zepf Medizintechnik GmbH. It is crucial to avoid the use of corrosive chemicals that could alter the surface of the steel. Regular visual inspection of the joint and the condition of the beaks is imperative to maintain gripping performance during pedodontic extraction.

Who is the manufacturer and what standards are respected?

The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, a recognized player in the manufacture of high-precision dental and surgical instrumentation. Although the specific regulatory class and CE marking are not detailed in the provided source data, this product is manufactured according to the industrial quality standards of the German company. Practitioners are invited to refer to the instructions for use and the markings on the original packaging to confirm compliance with current regulations (MDR). The technical reference 14.150.05 allows for full traceability of the device through the supplier Delynov.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument