What is the EXLOG® FORCEPS FIG. 35N for upper premolars?
The EXLOG® FORCEPS FIG. 35N is a manual surgical instrument designed by the manufacturer Helmut Zepf. This device, bearing reference 15.235.07, belongs to the category of extraction instruments (forceps). Its structure is specifically adapted to the morphology of the premolars of the upper arch. As part of the EXLOG® range, it benefits from a design focused on the efficient transmission of force during exodontia procedures. This instrument is a standard tool for practitioners performing simple or complex extractions in dental offices or hospital settings.
What are the clinical indications for this Helmut Zepf forceps?
This forceps is indicated for the avulsion of upper premolars. In oral and implant surgery, it is used to grasp the tooth at the cervical level in order to perform the rotation and tilting movements necessary to break the periodontal ligament. Its use occurs during irreversible carious pathologies, tooth fractures, for orthodontic reasons, or before the implementation of an implantation protocol. The shape of Figure 35N ensures precise adaptation to the root surfaces of the maxillary premolars, allowing controlled manipulation by the dental surgeon.
What are the technical characteristics of reference 15.235.07?
The Helmut Zepf forceps reference 15.235.07 is distinguished by its FIG. 35N configuration. It is designed to offer optimal grip of the upper premolars. The geometry of the beaks is studied to match the convexity of the roots of these specific teeth, thereby reducing the risk of slippage or crown fracture during extraction. Although precise details on the alloy are not specified in the source data, this type of Helmut Zepf instrument is traditionally manufactured to withstand repeated sterilization cycles in an autoclave, guaranteeing longevity in accordance with the requirements of dental surgery technical platforms.
What are the contraindications for the use of this instrument?
The contraindications for the use of the EXLOG® FIG. 35N forceps are mainly related to clinical situations where traditional manual extraction is inappropriate. This includes cases of teeth presenting severe ankylosis requiring an approach by root separation or alveolectomy. It must not be used on teeth other than upper premolars, as the inadequacy of the beak shape could lead to lesions of the surrounding soft tissues or alveolar bone fractures. As with any metallic instrument, its use is contraindicated in patients with a known hypersensitivity to the components of the alloy, in accordance with the manufacturer's general recommendations.
What are the maintenance and durability precautions?
As a non-resorbable and reusable instrument, the Helmut Zepf forceps requires a rigorous decontamination and sterilization protocol after each use. The manufacturer's instructions regarding manual or ultrasonic cleaning, as well as steam sterilization parameters, should be followed. The practitioner must regularly inspect the condition of the beaks and the hinge to ensure the absence of corrosion or mechanical fatigue. Proper maintenance ensures that the instrument retains its gripping properties and fluidity of movement, essential for patient safety and the efficiency of the surgical gesture.
Who is the manufacturer and what standards are respected?
The official manufacturer of this device is Helmut Zepf Medizintechnik GmbH, a recognized company in the field of dental and surgical instrumentation. This product is marketed under the Helmut Zepf brand, a guarantee of quality in the oral surgery sector. Although the specific regulatory class and CE marking are not detailed in the current technical sheet, Helmut Zepf products are developed according to strict manufacturing standards. For any precise information on compliance certifications or ISO standards applied to reference 15.235.07, it is recommended to refer to the technical documentation provided by the manufacturer or to consult the instructions for use attached to the instrument.