The Luxateur droit de 3 millimètres figure 1 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 17.006.01.
  • Reserved for healthcare professionals. Read instructions carefully before use.

63.53 € 63.53 EUR 63.53 € Tax Included

63.53 € Tax Included

(63.53 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the 3 millimeter straight luxator figure 1?

The 3 millimeter straight luxator figure 1 is a precision manual instrument designed by Helmut Zepf Medizintechnik GmbH. This device consists of a straight active part with a width of 3mm, manufactured from high-quality medical stainless steel. Unlike a standard elevator, its blade is thinner to allow for precise insertion into the periodontal space. This tool is specifically developed to facilitate the initial stages of extraction by sectioning the supporting ligaments of the tooth. Its rigid structure and ergonomic design meet the requirements of dental surgeons seeking a reliable instrument for dental luxation. It is delivered non-sterile and requires a complete cleaning and sterilization protocol before each intervention in the practice.

What are the clinical indications for this 3mm dental luxator?

The use of this 3mm dental luxator is indicated in oral surgery procedures requiring root mobilization prior to avulsion. It is particularly effective for the expansion of alveolar walls and the sectioning of the periodontal ligament. In clinical practice, purchasing a straight luxator allows the practitioner to intervene on single roots or multi-rooted teeth after separation. Its use is recommended to reduce mechanical resistance during extraction, thereby minimizing the risk of root fracture or excessive trauma to the alveolar bone. This Helmut Zepf instrument finds its place in conventional extraction protocols as well as in site preparation for immediate implant loading, where preserving the integrity of the bone plate is an absolute priority.

What are the technical characteristics of this device?

The straight dental luxator referenced under code 17.006.01 features rigorous technical specifications. Its active tip measures exactly 3 millimeters wide, offering an ideal compromise between insertion thinness and mechanical resistance. Manufactured by Helmut Zepf Medizintechnik GmbH, the instrument is machined from medical stainless steel selected for its biocompatibility and its ability to maintain an effective sharp edge after several sterilization cycles. As a Class I device, it meets European manufacturing standards for non-invasive or short-term invasive manual instruments. Its straight shape (figure 1) facilitates direct access to the anterior and premolar sectors. The device is designed to withstand the moderate torsion and leverage stresses inherent in luxation, provided that the cutting edges show no visible damage.

What are the contraindications for the use of this instrument?

The main contraindication mentioned by the manufacturer Helmut Zepf concerns hypersensitivity reactions. Metal intolerance in a patient, particularly to components of medical stainless steel, can lead to adverse reactions during contact with the instrument. If an allergic reaction or intolerance is suspected or triggered during the procedure, the intervention must be stopped immediately and necessary medical measures must be taken. Furthermore, the use of the instrument is strictly prohibited if it shows visible damage or wear, such as cracks, breaks, or defects on the cutting edges. The use of a damaged product would compromise patient safety and the effectiveness of the surgical act. Finally, its use is reserved exclusively for qualified healthcare professionals.

What are the maintenance and sterilization precautions?

As a reusable instrument, the 3mm straight luxator must strictly follow a reprocessing protocol. Products are delivered non-sterile by the manufacturer. Before the first use, as well as after each subsequent use, the instrument must be cleaned, disinfected, and sterilized. It is crucial to visually inspect the device for any signs of wear, corrosion, or deformation before each cycle. Due to the robust design and materials used by Helmut Zepf, there is no defined maximum limit of processing cycles, as long as the physical and functional integrity of the instrument is preserved. Thorough cleaning of the cutting edges is essential to ensure luxation performance during subsequent interventions. Compatibility with other cleaning and disinfection products must also be verified beforehand.

Who is the manufacturer and what standards are respected?

This luxator is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Seitingen-Oberflacht, Germany. This medical device belongs to Class I according to current regulations. The manufacturer guarantees that the instrument is produced according to high quality standards, using medical stainless steel compliant with dental surgery requirements. Although specific CE marking is not detailed in the source data, compliance with medical device directives for Class Ir (MDC0483) is mentioned for the reprocessing process. Helmut Zepf Medizintechnik GmbH ensures the traceability and safety of its manual instruments, intended exclusively for professional use by practitioners trained in oral surgery and extraction techniques.