Elevator Approximal Helmut Zepf (17.008.03)
The Élévateur approximal Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 17.008.03.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Helmut Zepf approximal elevator (17.008.03)?
The Helmut Zepf approximal elevator, referenced under code 17.008.03, is a high-precision manual instrument manufactured by Helmut Zepf Medizintechnik GmbH. Designed in medical stainless steel, this tool is specifically developed for oral surgery interventions requiring delicate manipulation of dental structures. Its rigid structure and composition make it a reliable device for practitioners seeking a high-performance surgical dental elevator. It belongs to Class I of medical devices, guaranteeing its compliance with regulatory requirements for non-invasive or invasive instruments for temporary use.
What are the clinical indications for this dental approximal elevator?
This instrument is primarily indicated for lifting teeth or extracting residual dental roots during an extraction procedure. In clinical practice, the Helmut Zepf approximal elevator allows for the breaking of periodontal ligament fibers and the creation of sufficient space to mobilize the tooth. It is particularly useful in cases of fractured or deeply anchored roots where access is limited. Its use is strictly reserved for qualified healthcare professionals, such as dental surgeons and stomatologists, operating within the framework of simple or complex exodontia procedures.
What are the technical characteristics of the instrument?
The Helmut Zepf elevator (ref. 17.008.03) is distinguished by its manufacture in medical grade stainless steel, offering optimal resistance to mechanical stress during luxation. Although the manufacturer does not define a maximum limit for processing cycles due to the robust design and materials used, the instrument must undergo rigorous inspection before each use. The practitioner must check for the absence of visible damage such as cracks, breaks, or defects on the cutting edges. Any instrument showing notable wear must be discarded to ensure patient safety.
What are the contraindications for the use of this instrument?
The main contraindication related to the use of this elevator is known hypersensitivity or intolerance of the patient to metals, particularly to the components of medical stainless steel. A hypersensitivity reaction can be triggered upon contact with the instrument. If such a reaction occurs during the intervention, the procedure must be immediately interrupted and necessary medical measures must be taken. It is therefore crucial to evaluate the patient's allergic history before any manipulation with this Helmut Zepf instrument.
What are the maintenance and sterilization precautions?
Helmut Zepf Medizintechnik GmbH products are delivered non-sterile. Before the first use and after each subsequent use, the instrument must imperatively be cleaned, disinfected, and sterilized according to a complete protocol. It is essential to carry out thorough cleaning to remove all organic residue before the sterilization phase. The practitioner must also ensure the compatibility of the elevator with other products and equipment used. Rigorous maintenance is the guarantor of the instrument's longevity and the prevention of cross-contamination risks in the dental office.
Who is the manufacturer and what standards are respected?
The instrument is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Seitingen-Oberflacht, Germany. This medical device is classified as Class I according to current regulations. The manufacturer imposes strict safety instructions, emphasizing that the use of this high-quality dental elevator is reserved exclusively for healthcare professionals. Compliance with the cleaning and sterilization protocols described by Helmut Zepf is mandatory to maintain the device's conformity and ensure safe surgical practice.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.
Specifications
| Manufacturer | Helmut Zepf |
| Tags | |
|---|---|
| Tags | |