Nabers P2N Probes - Helmut Zepf (24.453.15) - Delynov
The Sondes Nabers P2N - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 24.453.15.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf Nabers P2N probe?
The Nabers P2N probe, referenced under code 24.453.15 by Helmut Zepf, is a manual diagnostic instrument used in periodontology. Manufactured from high-quality medical stainless steel, this furcation probe is distinguished by its curved shank and blunt tip, specifically designed to navigate the complex anatomy of inter-radicular areas. This non-sterile device is an essential tool for the clinical evaluation of horizontal attachment loss at the furcation entrances of molars and premolars. As an instrument from the brand Helmut Zepf Medizintechnik GmbH, it meets the durability and precision requirements expected by dental surgeons during thorough periodontal examinations.
What are the clinical indications for this furcation probe?
This periodontal furcation probe is primarily indicated for the exploration of furcation lesions in patients with periodontitis. It allows the practitioner to determine the class of involvement (Class I, II, or III according to Glickman) by evaluating the horizontal penetration of the instrument between the roots of multi-rooted teeth. Its use is essential during the initial diagnostic phase, as well as for post-therapeutic follow-up to verify the stability of periodontal tissues. The instrument is exclusively reserved for healthcare professionals trained in periodontal diagnostic techniques, ensuring safe handling and accurate reading of clinical parameters essential for establishing an appropriate treatment plan.
What are the technical characteristics of the 24.453.15 probe?
The Nabers P2N probe (24.453.15) is a single-block instrument designed by Helmut Zepf Medizintechnik GmbH. Its main feature lies in the specific curvature of its working part, optimized to match the morphology of furcation entrances. Made of medical stainless steel, it offers optimal resistance to corrosion and repeated sterilization cycles. This device belongs to Class I of medical devices. It is delivered in a non-sterile state, which requires a complete processing protocol before its first use in the practice. The design of the instrument does not define a maximum limit for processing cycles, although visible wear and surface integrity must be checked before each clinical intervention.
What are the contraindications for the use of this instrument?
The use of this furcation probe has a major contraindication related to known hypersensitivity or intolerance to metals, specifically to the medical stainless steel used in its composition. In the event of an allergic reaction or hypersensitivity triggered during contact with the patient's mucous membranes, the clinical procedure must be immediately interrupted and necessary medical measures must be taken. It is also prohibited to use the instrument if it shows visible damage such as cracks, breaks, or defects on the edges, as this could compromise patient safety or diagnostic accuracy. Rigorous visual inspection before each use is therefore imperative.
What are the maintenance and sterilization precautions?
Being delivered non-sterile, the Helmut Zepf Nabers probe must imperatively follow a complete cycle of cleaning, disinfection, and sterilization before the first use and after each subsequent use. The manufacturer specifies that it is crucial to clean each product before proceeding with sterilization to remove any organic residue. Although no maximum limit for processing cycles is defined by the product design or materials used, the practitioner must verify compatibility with other cleaning products used. Any instrument showing signs of wear, corrosion, or deformation must be removed from service to ensure the safety of care and the reliability of the periodontal measurements performed.
Who is the manufacturer and what standards are respected?
The Nabers P2N probe is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Seitingen-Oberflacht, Germany. This medical device is classified as Class I according to current regulations. Compliance with rigorous manufacturing protocols by Helmut Zepf ensures the instrument's conformity with safety and performance requirements for manual medical devices. As a Class I product, it meets the quality standards for medical stainless steel (MDC0483). Healthcare professionals can refer to the manufacturer's instructions for reprocessing and maintenance, thus ensuring the long-term maintenance of the probe's technical properties in a demanding clinical environment.
State of the art
Surgical medical consumables play a decisive role in operative safety.