The Micro-sonde double - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 24.725.21.
  • Reserved for healthcare professionals. Read instructions carefully before use.

62.55 € 62.55 EUR 62.55 € Tax Included

62.55 € Tax Included

(62.55 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf double micro-probe?

The Helmut Zepf double micro-probe, referenced under code 24.725.21, is a manual instrument designed by Helmut Zepf Medizintechnik GmbH. This Class I medical device is manufactured from medical-grade stainless steel, ensuring resistance adapted to the constraints of clinical exploration. As a dental double micro probe, it features two active ends allowing the practitioner to have two exploration configurations on a single handle, thus optimizing efficiency during oral cavity examinations.

What are the clinical indications?

This periodontal micro probe is indicated as a manual dental instrument for exploration and diagnosis. It is primarily used in periodontology and oral surgery to probe pockets, check the integrity of root surfaces, or detect enamel irregularities. Its fine design makes it an ideal fine periodontal probe for narrow areas where standard probes might lack precision. It assists the practitioner in establishing an accurate diagnosis before any therapeutic or surgical procedure.

What are the technical characteristics?

The Helmut Zepf double micro-probe (24.725.21) is distinguished by its bifid structure in medical stainless steel. Delivered non-sterile by the manufacturer Helmut Zepf Medizintechnik GmbH, it requires a complete reprocessing cycle before each use. Although the product design and materials used do not allow for a maximum limit of treatment cycles to be defined, the instrument must be visually inspected for any cracks, breaks, or defects on the active parts before any use.

What are the contraindications for use?

The main contraindication mentioned by the manufacturer Helmut Zepf concerns known hypersensitivity to metals. As the instrument is composed of medical stainless steel, contact with the patient may trigger an intolerance reaction. In the event of a hypersensitivity reaction during the examination, the procedure must be stopped immediately and the necessary medical measures must be taken. It is therefore imperative to check the patient's allergic history before any use of this manual instrument.

What are the maintenance and sterilization precautions?

Like any Helmut Zepf instrument, this double micro probe must imperatively be cleaned, disinfected, and sterilized before the first use and after each subsequent use. The reprocessing process must be complete to ensure the safety of the patient and the practitioner. It is crucial to check for the absence of visible damage such as cracks or excessive wear of the tips. The use of damaged or worn products is strictly prohibited to maintain the integrity of the care provided.

Who is the manufacturer and what standards are met?

The device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. It is a Class I medical device (Class Ir according to the mentioned nomenclature). In accordance with the manufacturer's directives, the use of this micro probe is strictly reserved for qualified healthcare professionals. Compliance with cleaning and sterilization protocols is the responsibility of the practitioner, as is verifying compatibility with other products used during the intervention.


State of the art

Surgical medical consumables play a decisive role in operative safety.

Specifications

Manufacturer Helmut Zepf
Tags
Tags
Instrument