LUCAS Double-Ended Surgical Curettes, 3 mm, Fig. 2 - Helmut Zepf (41.855.02) - Delynov
The Curettes chirurgicales LUCAS doubles, 3 mm, Fig. 2 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 41.855.02.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the LUCAS double 3 mm surgical curette?
The Lucas curette n2 is a manual surgical instrument with a double active end, specifically designed for oral surgery procedures. This Helmut Zepf model features a symmetrical structure with two spoon-shaped working parts, each measuring 3mm in diameter. The instrument is developed by Helmut Zepf Medizintechnik GmbH, a manufacturer recognized for the quality of its instrumentation. Its design allows for efficient manipulation during soft tissue curettage or bone site preparation. Reference 41.855.02 corresponds precisely to Figure 2 of this range, offering an ideal compromise between precision and tissue gripping capacity.
What are the clinical indications for this instrument?
The purchase of a Lucas-type surgical curette is primarily indicated for alveolar curettage after tooth extraction. It allows the surgeon to systematically eliminate infectious debris, periodontal ligament residues, or inflammatory tissues present in the socket. In implant surgery, it is used to clean the recipient site and ensure the absence of soft tissue before implant placement. It is also employed for the enucleation of small periapical cysts or for removing granulation tissue during periodontal surgeries. Its 3mm size makes it particularly suitable for molar or premolar sockets.
What are the technical characteristics of the 41.855.02 curette?
The 3mm Lucas curette (reference 41.855.02) is distinguished by its precise geometric characteristics. It is a double-ended instrument whose active ends are angled to allow ergonomic access to the posterior and anterior areas of the oral cavity. The 3mm diameter of the working part (Fig. 2) allows for effective curettage without exerting excessive pressure on the bone walls. The handle is designed to offer a stable grip, essential during scraping or excision movements. Manufactured by Helmut Zepf, this curette meets the durability and resistance requirements necessary to withstand repeated sterilization cycles in the dental office.
What are the contraindications for using this instrument?
There are no specific absolute medical contraindications to using the Lucas curette, other than those related to the surgical procedure itself. However, its use should be avoided on fragile anatomical structures such as the sinus floor or the inferior alveolar canal if radiological proximity is too significant, to prevent any risk of perforation or nerve injury. The use of an instrument with a dull or damaged end is strongly discouraged, as this could lead to unnecessary tissue trauma or surgical inefficiency. The practitioner must adapt the choice of diameter (3mm here) to the morphology of the treated area.
What are the maintenance precautions for this non-resorbable device?
As a reusable surgical instrument, this Helmut Zepf curette requires a rigorous decontamination and sterilization protocol after each use. Although the exact material is not specified in the source data, this type of instrumentation must be cleaned manually or in an ultrasonic bath to remove all organic debris before autoclaving. It is recommended to use neutral pH cleaning solutions to preserve the integrity of the active surfaces. A visual check of the sharpness of the 3mm spoons is recommended to guarantee the effectiveness of the curettage during subsequent interventions. Storage in a dry and sterile environment is imperative until the next procedure.
Who is the manufacturer and what standards are respected?
The device is manufactured by Helmut Zepf Medizintechnik GmbH, a company specializing in high-precision surgical instrumentation. Specific regulatory information such as the risk class, CE marking, or ISO standards are not detailed in the current technical sheet for this product. For details on certificates of conformity or Instructions for Use (IFU) compliant with the European Medical Device Regulation (MDR), it is advisable to refer directly to the accompanying leaflet provided by the manufacturer or to contact Delynov's technical service. Compliance with standard sterilization protocols remains the norm for this type of manual instrumentation.
State of the art
Specialized surgical instrumentation is evolving towards ergonomic designs.
Specifications
| Manufacturer | Helmut Zepf |
| Tags | |
|---|---|
| Tags | |