The Grattoir à os Bone Scraper II diamètre 6 - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 47.957.15.
- Reserved for healthcare professionals. Read instructions carefully before use.
What is the Bone Scraper II?
The Bone Scraper II (reference 47.957.15) from Helmut Zepf is a manual instrument specifically designed for bone surgery. Manufactured from medical stainless steel by Helmut Zepf Medizintechnik GmbH, this diameter 6 device is used as a dental surgery bone scraper. Its structure allows for the efficient harvesting of cortical bone chips. It belongs to the category of reusable consumables, requiring a rigorous cleaning and sterilization protocol before each use to ensure clinical safety during interventions.
What are the clinical indications?
This dental bone scraper is indicated for harvesting autologous bone during oral and implant surgeries. It is used by healthcare professionals to collect bone tissue from the patient themselves, serving as an autologous bone harvester for filling bone defects or alveolar volume augmentation. Its use is strictly reserved for qualified practitioners mastering intra-oral bone harvesting techniques. The instrument allows for obtaining quality bone particles while controlling the harvesting area.
What are the technical characteristics?
The Bone Scraper II is characterized by a diameter of 6 mm, optimized for standard surgical access areas. Designed by Helmut Zepf, it is entirely made of medical stainless steel, a material chosen for its resistance and compatibility with sterilization cycles. As a Class I instrument, it meets the manufacturing requirements for manual medical devices. The manufacturer specifies that due to its design and the materials used, there is no defined maximum limit of processing cycles, although the wear of the cutting edges must be checked before each use.
What are the contraindications for use?
The main contraindication mentioned by the manufacturer Helmut Medizintechnik Gmbh concerns known hypersensitivity to metal components. Metal intolerance in the patient, following contact with the medical stainless steel of the instrument, can trigger an allergic reaction. If such a reaction occurs during the intervention, the procedure must be immediately stopped and necessary medical measures must be taken. Additionally, the use of the instrument is prohibited if it shows visible damage, such as cracks, breaks, or defects on the cutting edges.
What are the maintenance and reprocessing precautions?
The Bone Scraper II is delivered non-sterile. It is imperative to clean, disinfect, and sterilize the instrument before the first use and after each subsequent use. The practitioner must visually inspect the device for any sign of wear or damage before use; the use of damaged products is strictly prohibited. Although no strict limit on processing cycles is set, the longevity of the instrument depends on compliance with reprocessing protocols and verification of the integrity of the sharp edges to maintain the efficiency of the bone scraping.
Who is the manufacturer and what standards are respected?
The device is manufactured by Helmut Zepf Medizintechnik GmbH, located in Seitingen-Oberflacht, Germany. This bone scraper is classified as a Class I medical device according to current regulations. The manufacturer ensures the instrument's compliance with quality standards for manual dental instruments. All safety instructions, including mandatory cleaning and sterilization, must be followed by the healthcare professionals for whom this product is exclusively reserved, thus guaranteeing use in accordance with the regulatory requirements of the medical sector.
State of the art
Surgical medical consumables play a decisive role in operative safety.
Specifications
| Manufacturer | Helmut Zepf |
| Tags | |
|---|---|
| Tags | |