Osteotomy Kit Helmut Zepf for Dental Surgery (47.961.00) - Delynov
The Kit d'ostéotomie Helmut Zepf pour is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.
- Compliance: Medical device Class I.
- Manufacturer: Helmut Zepf Medizintechnik GmbH.
- Reference: 47.961.00.
- Reserved for healthcare professionals. Read instructions carefully before use.
| Manufacturer: Helmut Zepf |
Complete your order
Our customers often order these together
What is the Helmut Zepf Osteotomy Kit (47.961.00)?
The Helmut Zepf Osteotomy Kit, referenced under code 47.961.00, is a set of manual instruments specifically developed for bone surgery. This osteotomy set is manufactured from medical-grade stainless steel, ensuring resistance adapted to the constraints of surgical interventions. As a Class I medical device, it is designed by Helmut Zepf Medizintechnik GmbH to meet the requirements of practitioners in implantology and oral surgery. This equipment is delivered non-sterile and requires a complete preparation protocol before any clinical use.
What are the clinical indications for this kit?
Ce set d'ostéotomie est indiqué pour toutes les procédures manuelles de chirurgie orale nécessitant une intervention sur le tissu osseux. Il est principalement utilisé lors des phases d'ostéotomie pour préparer le site implantaire ou pour effectuer des corrections structurelles. Son utilisation est strictement réservée aux professionnels de santé qualifiés. Les instruments du kit permettent des gestes précis de coupe et de manipulation osseuse, facilitant ainsi les protocoles de chirurgie orale et parodontale où l'instrumentation manuelle est recommandée par Helmut Zepf.
What are the technical characteristics of this instrument set?
Le kit d'ostéotomie Helmut Zepf se caractérise par l'utilisation d'acier inoxydable médical de haute qualité. Chaque instrument manuel inclus dans ce kit est conçu pour résister à des cycles répétés de nettoyage, de désinfection et de stérilisation. En raison de la conception robuste et des matériaux utilisés, il n'y a pas de limite maximale définie pour le nombre de cycles de traitement, tant que l'intégrité physique de l'instrument est préservée. Il est impératif de vérifier l'absence de dommages visibles, tels que des fissures ou des défauts sur les bords tranchants, avant chaque intervention.
What are the contraindications for the use of these instruments?
The main contraindication related to the use of this kit concerns known patient hypersensitivity to metals. Contact with medical stainless steel can trigger an allergic reaction or intolerance in certain individuals. If such a hypersensitivity reaction occurs during the procedure, the manufacturer Helmut Zepf stipulates that the intervention must be stopped immediately and necessary medical measures must be taken. Additionally, the use of instruments showing signs of wear, breakage, or defects on the sharp edges is formally prohibited to ensure patient safety.
What are the maintenance and sterilization precautions?
The instruments in this osteotomy kit are delivered non-sterile. According to the safety instructions from Helmut Zepf Medizintechnik GmbH, all products must imperatively be cleaned, disinfected, and sterilized before the first use, as well as after each subsequent use. Reprocessing must be complete and rigorous. The practitioner must inspect each instrument to detect any trace of wear or corrosion. The use of damaged products is prohibited. Compatibility with other devices used during the intervention must also be verified beforehand to ensure the smooth progress of the surgery.
Who is the manufacturer and what standards are respected?
Le fabricant officiel de cet instrument est la société Helmut Zepf Medizintechnik GmbH, située à Seitingen-Oberflacht, Allemagne. Ce kit d'instruments est classé comme dispositif médical de Classe I selon la réglementation en vigueur. Nous assurons la traçabilité et la conformité de nos instruments en acier inoxydable destinés à la chirurgie orale manuelle. Le respect des protocoles de nettoyage et de stérilisation recommandés par Helmut Zepf est essentiel pour maintenir la conformité du dispositif et garantir la sécurité des soins lors de chaque acte d'ostéotomie.
State of the art
Single-use sterile surgical kits significantly reduce intraoperative contamination.