The Support en silicone - Helmut Zepf is a medical device manufactured by Helmut Zepf Medizintechnik GmbH.

  • Compliance: Medical device Class I.
  • Manufacturer: Helmut Zepf Medizintechnik GmbH.
  • Reference: 85.180.04.
  • Reserved for healthcare professionals. Read instructions carefully before use.

32.48 € 32.48 EUR 32.48 € Tax Included

32.48 € Tax Included

(32.48 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Helmut Zepf silicone holder (85.180.04)?

The Helmut Zepf silicone holder, reference 85.180.04, is an instrumentation management accessory designed for use within cleaning and sterilization cassettes. This silicone instrument holder allows manual devices to be wedged and stabilized, thus preventing friction and mechanical damage to cutting edges or delicate tips. Manufactured by Helmut Zepf Medizintechnik GmbH, this component is specifically adapted to the demanding environments of dental surgery and implantology practices. Its flexible yet resistant structure is designed to withstand repeated cycles in hot and humid environments, guaranteeing optimal organization of the technical platform.

What are the clinical indications for this silicone holder?

Although the holder itself is not a cutting or insertion instrument, its use is indicated for the preparation and maintenance of any manual dental instrument used in oral, periodontal, or implant surgery. As a silicone cassette holder, it facilitates compliance with hygiene protocols by keeping instruments spaced apart, allowing full exposure to disinfection agents and steam during sterilization. It is particularly recommended for practitioners wishing to extend the life of their precision instrumentation by avoiding direct shocks during pre- and post-operative handling.

What are the technical characteristics of this holder?

The Helmut Zepf silicone holder (85.180.04) is characterized by high thermal resistance, essential for an autoclave silicone holder. Its design allows for easy insertion into the rails of standard sterilization cassettes. The silicone material used is chosen for its chemical neutrality and its ability not to retain biological residues after appropriate cleaning. This silicone instrument holder is delivered non-sterile, in accordance with the standards of the manufacturer Helmut Zepf Medizintechnik GmbH. It belongs to Class I of medical devices. Its geometry is studied to adapt to various instrument handle diameters, ensuring a firm hold without excessive compression of the material.

What are the contraindications for the use of this device?

Direct contraindications related to the silicone holder are limited, but it should be noted that the use of stainless steel instruments held by this support may cause hypersensitivity reactions or metal intolerance in certain patients in the event of direct contact. If such an allergic reaction occurs during the procedure, the procedure must be immediately interrupted and the necessary clinical measures applied. Furthermore, it is imperative never to use holders showing visible damage such as cracks or breaks, as this could compromise the effectiveness of the cleaning and sterilization of the housed instrumentation.

What are the maintenance and reprocessing precautions?

Like any reprocessing accessory, this sterilization cassette silicone holder must be rigorously cleaned, disinfected, and sterilized before the first use, and then after each subsequent use. The manufacturer Helmut Zepf specifies that due to the design of the product and the materials used, there is no defined maximum limit of treatment cycles, as long as the product does not show signs of manifest wear. Practitioners must visually inspect the holder before each cycle to detect any degradation. The use of damaged products is strictly prohibited to guarantee the aseptic safety of the care chain. This device is exclusively reserved for qualified healthcare professionals.

Who is the manufacturer and what standards are respected?

The holder is manufactured by Helmut Zepf Medizintechnik GmbH, a recognized manufacturer located in Germany. This medical device is classified as Class I according to current regulations. Compliance with cleaning and sterilization protocols is the responsibility of the healthcare professional, in accordance with the instructions provided by Helmut Zepf. The product must be checked for compatibility with other elements of the sterilization cassette before use. As a Class I device, it meets the safety and performance requirements for manual instrumentation accessories in the dental environment, thus ensuring traceability and manufacturing quality consistent with the expectations of dental surgeons.