Skip to Content

Lime Orban number 12/13 handle number 6 - Hu-Friedy - Delynov

https://www.delynov.fr/web/image/product.template/21109/image_1920?unique=d8c89d8

The Lime Orban #12/13 manche #6 - Hu-Friedy is a medical device manufactured by Hu-Friedy Mfg. Co., LLC.

  • Compliance: Medical device Class I.
  • Manufacturer: Hu-Friedy Mfg. Co., LLC.
  • Reserved for healthcare professionals. Read instructions carefully before use.

78.45 € 78.45 EUR 78.45 € Tax Included

78.45 € Tax Included

(0.00 € / Units)
  • Manufacturer

This combination does not exist.

Instrument

What is the Hu-Friedy Orban #12/13 file with #6 handle?

The Orban #12/13 file, combined with the #6 handle, is a high-precision manual instrument manufactured by Hu-Friedy Mfg. Co., LLC. This device is specifically designed for periodontal interventions, allowing for meticulous work on root surfaces. As an instrument in the INSTRU category, it meets the quality requirements of a recognized manufacturer like Hu-Friedy. Its structure is optimized to provide a precise tactile response during the removal of calcified deposits. This medical device is intended exclusively for professional use in dental offices or hospital settings for oral surgeries.

What are the clinical indications for this periodontal file?

The use of the periodontal Orban file is indicated for the treatment of periodontal diseases, specifically during the scaling and deep root planing phases. It is used to fragment very adherent calculus deposits that standard curettes cannot always dislodge. This instrument is also useful for finishing root surfaces and managing soft tissues during periodontal surgeries. Its double-ended design (12/13) allows access to different tooth surfaces, facilitating mechanical debridement in complex periodontal pockets or restricted access areas.

What are the technical characteristics of this instrument?

The Orban #12/13 file is characterized by a double active-end configuration, mounted on a #6 type handle from Hu-Friedy. This handle ergonomics is designed to ensure a stable grip during scraping and smoothing movements. The instrument belongs to Class I according to medical device regulations. The technical design is based on the expertise of Hu-Friedy Mfg. Co., LLC, guaranteeing adequate rigidity to transmit the force necessary for calculus fragmentation without compromising the tactile sensitivity essential for the clinician to identify root irregularities.

What are the contraindications for the use of the Orban file?

According to information provided by the manufacturer Hu-Friedy, the use of this instrument is reserved exclusively for qualified healthcare professionals. Specific contraindications are not detailed in the raw technical documentation, but use must be avoided by anyone not possessing the required clinical training for periodontal surgery. It is imperative to read the instructions for use carefully before any intervention. As with any manual instrument, its use may be limited by extreme anatomical conditions or systemic pathologies of the patient contraindicating invasive dental care.

What are the maintenance precautions for this non-resorbable instrument?

As it is a manual metallic instrument and not a resorbable device, the Orban #12/13 file requires a rigorous sterilization protocol between each patient. Precautions include cleaning, disinfection, and sterilization in accordance with current protocols for reusable Class I medical devices. The practitioner must inspect the condition of the file's cutting edges before each use to ensure the effectiveness of the periodontal treatment. Inadequate maintenance can alter the properties of the steel and compromise clinical safety during oral surgery procedures.

Who is the manufacturer and what standards are respected?

The Orban #12/13 file is officially manufactured by Hu-Friedy Mfg. Co., LLC, located at 3232 N. Rockwell St. Chicago, Il 60618 USA. This medical device is classified as Class I. Compliance with manufacturing standards by Hu-Friedy ensures healthcare professionals an instrument that conforms to regulatory requirements for manual dental instrumentation. Any use must be preceded by a careful reading of the instructions provided by the manufacturer to guarantee use in accordance with the safety and clinical efficacy standards expected in dental surgery.


State of the art

Specialized surgical instrumentation is evolving towards ergonomic designs.

Specifications

Manufacturer Hu-Friedy
Tags
Tags
Instrument