SERALENE non-absorbable blue (5/0) DSS-13 needle 50 CM box of 24 sutures - Serag & Wiessner (LO10171L) - Delynov
The SERALENE suture by Serag-Wiessner GmbH & Co. KG is a non-absorbable monofilament synthetic medical device, indicated for oral surgery and implantology where prolonged material stability is required.
- Type: Non-absorbable (suture removal required after healing).
- Needle: DSS-13 (13 mm), 3/8 circle, atraumatic triangular tip.
- Format: Thread length 50 cm, caliber 5/0 (USP).
- Packaging: Box of 24 single-use sterile sutures.
- Compliance: Medical device Class III, CE marking CE1014.
- Manufacturer: Serag-Wiessner GmbH & Co. KG.
| Manufacturer: Serag-Wiessner Suture Materials |
Complete your order
Our customers often order these together
What is SERALENE non-absorbable blue 5/0?
SERALENE is a monofilament, synthetic, non-absorbable surgical suture material manufactured by Serag-Wiessner. Made from polyvinylidene fluoride, this non-absorbable thread is distinguished by its smooth surface and homogeneous structure that limits bacterial adhesion. Dyed blue (solvent blue) for increased visibility during surgery, it features a 5/0 gauge suitable for delicate interventions. This Class III medical device meets the requirements of the European Pharmacopoeia for sterile non-absorbable sutures. Its monofilament configuration allows for smooth passage through tissues without a saw effect, thus ensuring tissue integrity during placement.
What are the clinical indications in oral surgery?
In clinical practice, SERALENE is used for soft tissue approximation requiring a non-absorbable suture. It is particularly recommended in periodontology and implantology for closing surgical sites where long-term stability is required. Its monofilament nature makes it an oral surgery polypropylene suture of choice for microsurgery techniques and thin flap sutures. It can also serve as a support thread or marking medium. Beyond the oral sphere, its indications extend to the central circulatory and nervous systems, as well as ophthalmology, confirming its versatility and high biological tolerance for sensitive body structures.
What are the technical characteristics of the DSS-13 needle?
The DSS-13 needle associated with this oral surgery suture is a 3/8 circle needle with a length of 13mm. It has an atraumatic reverse-cutting triangular point, specifically designed to penetrate delicate tissues and thin mucous membranes without causing unnecessary tearing. This geometry allows for precise and controlled penetration, essential in oral surgery to ensure optimal healing. Manufactured from high-quality surgical steel by Serag-Wiessner GmbH & Co. KG, the DSS-13 needle maintains its sharpness throughout the procedure, facilitating the implantologist's work when handling dense or keratinized tissues.
What are the contraindications for the use of this suture?
The use of SERALENE is contraindicated in patients with a known hypersensitivity or allergy to polyvinylidene fluoride or the dye solvent blue (colour index nº 61568). As with any foreign body, prolonged contact with bile or urinary tracts can promote the formation of calculi. It is imperative that the practitioner adapts the choice of suture material and knotting techniques according to the clinical specificities of each patient and the treated indication. Before any use, it is necessary to refer to the instructions for use to become familiar with all warnings and precautions for use.
What are the precautions related to its non-absorbable nature?
As a non-absorbable oral surgery suture, SERALENE maintains its tensile strength permanently in the body. Unlike absorbable sutures, it does not undergo degradation by hydrolysis or proteolysis. This requires rigorous management of suture removal once clinical healing is achieved, generally after 7 to 14 days in oral surgery, depending on the practitioner's protocol. Handling must avoid any damage to the monofilament surface by sharp instruments, which could weaken the thread. Knot quality is crucial with polyvinylidene fluoride to prevent any slippage, given its low coefficient of friction.
Who is the manufacturer and what standards are respected?
SERALENE is manufactured by Serag-Wiessner GmbH & Co. KG, a company based in Naila, Germany. This medical device is certified Class III and bears the CE1014 marking, guaranteeing its compliance with the strictest European regulatory requirements for long-term implantable devices. The product is delivered in boxes of 24 sutures, each thread measuring 50cm in length with technical reference LO10171L. Compliance with the European Pharmacopoeia monograph "sterile non-absorbable sutures" ensures health professionals a consistent level of safety and performance for their most demanding surgical interventions.
State of the art
Modern synthetic sutures - absorbable or non-absorbable - are central to wound healing in oral surgery. Recent advances focus on reducing post-operative infections.