SERALON non-absorbable blue (5/0) DS-18 needle of 75 CM box of 24 sutures - Serag & Wiessner (VO103414) - Delynov
The SERALON suture by Serag-Wiessner GmbH & Co. KG is a non-absorbable monofilament synthetic medical device, indicated for oral surgery and implantology where prolonged material stability is required.
- Material: Polyamide (Nylon).
- Type: Non-absorbable (suture removal required after healing).
- Needle: DS-18 (18 mm), 3/8 circle, triangular reverse cutting tip.
- Format: Thread length 75 cm, caliber 5/0 (USP).
- Packaging: Box of 24 single-use sterile sutures.
- Compliance: Medical device Class IIb, CE marking CE1014.
- Manufacturer: Serag-Wiessner GmbH & Co. KG.
| Manufacturer: Serag-Wiessner Suture Materials |
Complete your order
Our customers often order these together
What is the blue SERALON (5/0) suture thread?
SERALON from the brand Serag-Wiessner is a synthetic and non-absorbable surgical suture material. It is composed of polyamide (nylon) and features a monofilament structure. This technical configuration is particularly valued in surgery because it offers a smooth surface that limits bacterial adhesion and facilitates sliding through tissues. This 5/0 size thread is colored blue using phthalocyanine to ensure excellent visibility in the surgical field. It is packaged in boxes of 24 sterile sutures, each thread measuring 75cm, which is ideal for oral surgery and implantology procedures requiring high precision.
What are the clinical indications for this Serag-Wiessner suture?
SERALON est indiqué pour la suture des tissus mous lorsqu'une suture non résorbable est requise. En pratique courante, ce fil de suture ophtalmique et de chirurgie orale est utilisé pour la fermeture de lambeaux, les chirurgies parodontales et les procédures d'implantologie. Sa nature non résorbable en fait un choix pertinent lorsque le praticien souhaite maintenir une tension stable pendant la phase initiale de cicatrisation. Bien que le polyamide soit un matériau synthétique inerte, il convient de noter qu'il peut être utilisé en chirurgie ophtalmique sous réserve du respect de précautions spécifiques liées à cette discipline. Ce dispositif répond aux exigences de la Pharmacopée Européenne pour les sutures stériles non résorbables.
What are the technical characteristics of the DS-18 needle?
The DS-18 needle mounted on this SERALON suture has specific characteristics for firm tissues. The code 'DS' means it is a 3/8 circle needle with a reverse cutting triangular tip. This geometry is designed to pass through dense tissues, such as keratinized gingiva, without risking tearing the flap edge, as the cutting base is oriented towards the outside of the curvature. The figure 18 indicates a needle body length of 18 mm. This dimension, combined with the 5/0 size of the thread, offers an optimal balance between fineness for micro-surgery and mechanical strength for standard approximation sutures.
What are the contraindications for the use of SERALON?
The use of SERALON by Serag-Wiessner presents strict contraindications defined by the manufacturer. It must never be used for procedures involving direct contact with the heart, the central circulatory system, or the central nervous system. Furthermore, its use is prohibited in patients with a known allergy to polyamide or to the dyes used (phthalocyanine blue). Another important limitation concerns very long-term stability: although classified as non-absorbable, polyamide may undergo a progressive loss of tensile strength in the body over time. Consequently, it must not be used when permanent and indefinite stability of the suture material is essential.
What are the precautions related to the non-absorbable nature of the thread?
As SERALON is a non-absorbable monofilament thread, it requires a specific knotting technique. Due to the high elasticity and shape memory of polyamide monofilament threads, the manufacturer Serag-Wiessner recommends performing one or two additional knots compared to a braided thread to guarantee the security and strength of the suture. Unlike absorbable materials, this thread must be manually removed once clinical healing is achieved. Vigilance is also required in areas in contact with saline solutions (biliary or urinary tracts) where, like any foreign body, it could promote the formation of calculi, although this risk is marginal in oral surgery.
Who is the manufacturer and what standards are met by this product?
Ce dispositif médical est fabriqué par Serag-Wiessner GmbH & Co. KG, une entreprise reconnue basée à Naila, en Allemagne. Le produit est conforme aux normes européennes les plus strictes en matière de sécurité et de performance, bénéficiant d'un marquage CE1014. Il est classé comme dispositif médical de Classe IIb selon la réglementation en vigueur. La fabrication est conforme à la monographie de la Pharmacopée Européenne en vigueur relative aux fils de suture stériles non résorbables (fila non resorbiliasterilia). La référence VO103414 garantit la traçabilité du produit, assurant aux praticiens de chirurgie orale, d'implantologie et de parodontologie l'utilisation d'un matériel fiable et certifié pour leurs procédures opératoires.
State of the art
Modern synthetic sutures - absorbable or non-absorbable - are central to wound healing in oral surgery. Recent advances focus on reducing post-operative infections.