SERALON non-absorbable blue (4/0) DS-15 needle 75 CM box of 24 sutures - Serag & Wiessner (VO153413) - Delynov
The SERALON suture by Serag-Wiessner GmbH & Co. KG is a non-absorbable monofilament synthetic medical device, indicated for oral surgery and implantology where prolonged material stability is required.
- Material: Polyamide (Nylon).
- Type: Non-absorbable (suture removal required after healing).
- Needle: DS-15 (15 mm), 3/8 circle, triangular reverse cutting tip.
- Format: Thread length 75 cm, caliber 4/0 (USP).
- Packaging: Box of 24 single-use sterile sutures.
- Compliance: Medical device Class IIb, CE marking CE1014.
- Manufacturer: Serag-Wiessner GmbH & Co. KG.
| Manufacturer: Serag-Wiessner Suture Materials |
Complete your order
Our customers often order these together
What is non-absorbable SERALON 4/0?
SERALON by Serag-Wiessner is a synthetic, non-absorbable surgical suture material made from polyamide. This thread features a monofilament structure, giving it a smooth and uniform surface. This technical characteristic is essential in oral surgery as it prevents the wicking effect and significantly reduces the transport of microorganisms along the thread. Blue in color due to phthalocyanine pigment, it ensures excellent visibility during placement and removal. This medical device complies with the European Pharmacopoeia for sterile non-absorbable sutures, guaranteeing biocompatibility and tensile strength adapted to current clinical requirements.
What are the clinical indications?
Although the general intended use is surgical suture, the 4/0 calibre is particularly suitable for oral surgery, implantology, and periodontology interventions. Purchasing this type of oral surgery suture thread is recommended for the closure of surgical sites requiring maintenance of tissue integrity during the primary healing phase. Its monofilament structure makes it a preferred choice for mucoperiosteal flap sutures where post-operative hygiene is critical. It is used to secure grafts, close extraction sites, or stabilize soft tissues around healing abutments. The final choice of material must, however, take into account the specific characteristics of each clinical situation and the suture techniques employed.
What are the technical characteristics of the DS-15 needle?
The DS-15 needle equipped on this Serag-Wiessner suture has precise geometric specificities for dense tissues. The 'DS' code designates a 3/8 circle needle with a reverse cutting triangular tip. This configuration allows the cutting edge to be located on the outer curvature, thus minimizing the risk of tissue tearing towards the wound edge during the passage of the thread. The number '15' indicates a needle body length of 15mm. This dimension is ideal for navigating the restricted spaces of the oral cavity while providing a stable grip for the needle holder. Its ability to cross firm tissues without excessive resistance ensures a fluid gesture and reduced trauma.
What are the contraindications for use?
The use of SERALON is strictly contraindicated in direct contact with the heart, the central circulatory system, or the central nervous system. Furthermore, due to a progressive loss of tensile strength in vivo over time, this thread should not be used when prolonged and permanent mechanical stability of the suture material is essential. It is also prohibited in patients with known hypersensitivity or allergies to polyamide or phthalocyanine blue dye. Like any foreign body, it may promote stone formation if it remains in prolonged contact with saline solutions, such as in the biliary or urinary tracts, although this use is far from the oral sphere.
What are the precautions related to the non-absorbable nature of the thread?
As SERALON is a non-absorbable suture, it must be manually removed once sufficient tissue healing is obtained. Particular attention must be paid to knot tying: due to the high elasticity and shape memory of polyamide monofilament threads, it is strongly recommended to perform one or two additional knots (safety knots) to guarantee suture stability and avoid any untimely loosening. In ophthalmic surgery, specific warnings also apply. It is advisable to refer to the instructions for use to adapt the suture technique to the physical properties of the monofilament, notably to compensate for its reduced friction coefficient.
Who is the manufacturer and what standards are met?
SERALON is manufactured by Serag-Wiessner GmbH & Co. KG, a company based in Naila, Germany, recognized for its expertise in suture devices. This product carries CE1014 marking, certifying its compliance with European safety and performance requirements. It is classified as a Class IIb medical device. Manufacturing complies with European Pharmacopoeia (EP) standards for sterile non-absorbable sutures. Each box of reference VO153413 contains 24 sutures of 75cm in length, guaranteeing optimal traceability and sterility for demanding surgical environments.
State of the art
Modern synthetic sutures - absorbable or non-absorbable - are central to wound healing in oral surgery. Recent advances focus on reducing post-operative infections.